LM3 Slim Line All-Purpose Submersible Transmitter

Brand: Winters Instruments

Specifications
  • Slimline probe is especially suited for applications with restricted space
  • Designed for continuous level measurement in water or other liquids with low viscosity
  • 316L Stainless Steel probe with stainless steel sensor for ease in cleaning
  • Available ranges from Inches WC: 0 to 400 up to psi: 0 to 300 (kPa: 0 to 2,068, bar: 0 to 20.68)
  • ±0.35% accuracy rating
  • NEMA 6P / IP68
  • Approved for outdoor use
  • Customizable

Specifications

Accuracy

  • 5 (kPa: 34.47, bar: 0.3447): 5 (kPa: 34.47, bar: 0.3447): < ± 0.25 % of Full Scale Output BFSL

Approvals & Certifications

  • CE
  • CSA
  • EMC (Electromagnetic Compatibility): Emission & Immunity According to EN 61326
  • RoHS

Burst Pressure

  • psi: 22 to 1,740 (kPa: 151.7 to 12,000, bar: 1.517 to 120)

Cable Material

  • Cable with Sheath: FEP (Black)
  • Cable with Sheath: PUR (Black)
  • Cable with Sheath: PVC - Grey

Capacitance

  • Cable Capacitance (Signal Line / Shield & Signal Line / Signal Line): 160 PF/m

Circuit Protection

  • Reverse Polarity Protection

Compensated Temperature

  • 0° to 70° C (32° to 158° F)

Consumption

  • Current: 25 mA - Max.

Diaphragm Material

  • 316L Stainless Steel

Enclosure, Body Material

  • 316Ti Stainless Steel

Environmental Protection

  • IP67
  • IP68
  • NEMA 6P

Inductance

  • Cable Inductance (Signal Line/Shield & Signal Line/Signal Line): 1 µH/m

Load Effect

  • 0.05 % of Full Scale Output / kiloohms

Nominal Pressure

  • psi: 0 to 15 (kPa: 0 to 103.4, bar: 0 to 1.034)

Output

  • 2-Wire: 4-20 mA/Vs = 12-36 Vdc

Overpressure & Static Pressure Limits

  • Overpressure psi: 15 to 1,450 (kPa: 103.4 to 10,000, bar: 1.034 to 100)

Power Supply Effect

  • 0.05 % of Full Scale Output / 10 V

Pressure Range

  • bar: 0 to 20.7
  • Inches WC: 0 to 400
  • kPa: 0 to 2,068
  • psi: 0 to 300

Process Temperature

  • -10° to 70° C (14° to 158° F)

Response Time

  • < 10 milliseconds

Seat / Seal Material

  • Seal: EPDM (Nordel)
  • Seal: FKM
  • Seal: Kalrez
  • Seal: Viton

Sensor, Probe Material

  • Probe: 316L Stainless Steel
  • Sensor: Stainless Steel for Ease in Cleaning

Stability

  • Long Term Stability: < ± 0.1 % of Full Scale Output/Year

Storage Temperature

  • -25° to 70° C (-13° to 158° F)

Temperature Effect

  • TC, Average: ± 0.07 % to ± 0.3 % of Full Scale Output/10 K
  • Tolerance Band: < ± 0.75 % to < ± 2 % of Full Scale Output

  • Appropriate for All Hazardous Areas Where An Intrinsically Safe Rating is Required
  • Chemical & Sewage Treatment Installations
  • Designed for Continuous Level Measurement in Water or other Liquids with Low Viscosity
  • Oil & Gas Applications

show more