LIM Aggressive Media Transmitter

Brand: Winters Instruments

Specifications
  • Universal transmitter with a high level of accuracy and stability
  • Designed especially for aggressive media
  • Rugged stainless steel construction with ceramic sensor
  • Available ranges include Inches Hg: -30 up to psi: 0 to 8,700 (kPa: 0 to 59,984, bar: 599.8)
  • Wide range of mechanical and electrical connections
  • 0.5% FSO accuracy
  • NEMA 4X and 6P / IP65 and IP67
  • CE, CSA and RoHS compliant
  • Approved for outdoor use
  • Customizable

Specifications

Accuracy

  • ± 0.5 % of Full Scale Output, IEC 60770

Approvals & Certifications

  • CE
  • CSA
  • RoHS

BSP Connection

  • G 1/2” Male Optional
  • G 1/4” Male

Cable Length

  • 6.56 feet (2 metres)

Cable Material

  • Cable Outlet: PVC

Circuit Protection

  • EMI/RFI Protected: Emission & Immunity According to EN 61326
  • Reverse Polarity Protection
  • Short Circuit Protected

Compensated Temperature

  • -25° to 85° C (-13° to 185° F)

Diaphragm Material

  • Ceramic Al₂O₃ 96 %

Electrical Connectors

  • Binder 723 (5-Pin)
  • DIN 43650-A (ISO 4400)
  • M12 x 1, 4-Pin

Enclosure, Body Material

  • 316L Stainless Steel

Environmental Protection

  • IP65
  • IP66
  • IP67
  • NEMA 4X
  • NEMA 6P

Load

  • Current 3-Wire, Rmax: 500 ohms
  • Voltage 3-Wire, Rmin: 10 kiloohms

Load Effect

  • 0.05 % of Full Scale Output / kiloohms

Materials of Construction

  • Pressure Port: 316L Stainless Steel

Media

  • Aggressive Media

Metric Connection

  • M20 x 1.5 Male

NPT Connection

  • 1/2” NPT Male
  • 1/4” NPT Male

Output

  • 2-Wire: 4-20 mA/Vs 8-32 Vdc
  • 3-Wire: 0-10 V/Vs 14-30 Vdc
  • 3-Wire: 0-20 mA/Vs 14-30 Vdc

Power Supply Effect

  • 0.05 % of Full Scale Output / 10 V

Pressure Range

  • bar: -1 to 599.8
  • Inches Hg: -30 to 0
  • kPa: -101.4 to 59,984
  • psi: -14.7 to 8,700

Process Temperature

  • -40° to 125° C (-40° to 257° F)

Response Time

  • ≤ 10 milliseconds

Seat / Seal Material

  • Seal: FKM 70 for PN psi: 1,450 (kPa: 10,000, bar: 100)

Sensor, Probe Material

  • Sensor: Ceramic

Shock

  • 500 G, 1 millisecond

Storage Temperature

  • -40° to 100° C (-40° to 212° F)

Temperature Effect

  • ≤ ± 0.2 % of Full Scale Output/10 K

Temperature Range

  • Electronics Environment: -40° to 85° C (-40° to 185° F)

Vibration

  • 10 G RMS at 20 to 2,000 Hz

  • Appropriate for Environmental Monitoring
  • Machine Tools & Presses
  • Test Equipment & Many Other Applications

show more