LTX20UL RF Capacitance Level Transmitter

Brand: Intempco Controls, Inc

Intempco LTX20 Series two-wire RF level transmitter provides highly reliable, low cost level indication and control that is suitable for all liquid level applications that do not leave a severe build-up on the sensing element. 

LTX20 transmitter measures the change in capacitance that occurs as the tank level changes, and outputs a standard loop-powered 4-20 mA signal. 

It uses a very high frequency, very low amplitude sensing circuitry to greatly minimize the effects of coating on the sensing probe. 

LTX20 is available as an integrally mounted package. A number of level sensing probes can be selected based on the application including bare stainless steel probe, rigid Teflon coated probe and rigid concentric. 

Available housings are aluminum and stainless steel NEMA 4X.
Features
  • Explosion proof design
  • Easy calibration
  • Consistent accuracy
  • Reliability
  • Housings
  • Mountings and probes

Specifications

Accuracy

  • ± 0.5 % of Full Span

Ambient Temperature Range

  • -40° to 70° C (-40° to 158° F)

Approvals & Certifications

  • CSA (C,US) - Class I, Div. 2, Groups A, B, C, D, Hazardous Locations
  • UL (C,US) - Class I, Div. 2, Groups A, B, C, D, Harzardous Locations

Calibration

  • Via 4 Push-Button Switches, Non-interactive Zero & Span

Capacitance

  • 10 to 10,000 PF

Conduit Connection

  • 1/2” NPT
  • 3/4” NPT

Damping Adjustment

  • 0 to 30 seconds

Display

  • Integral 4-Digit LCD

Enclosure, Body Material

  • Aluminum
  • Stainless Steel

Environmental Protection

  • IP66
  • NEMA 4X

Flange Size - 1-1/2” (DN 40)

  • 1-1/2” (DN 40) - 150# (ANSI B16.9)
  • 1-1/2” (DN 40) - 300# (ANSI B16.9)

Flange Size - 1” (DN 25)

  • 1” (DN 25) - 150# (ANSI B16.9)
  • 1” (DN 25) - 300# (ANSI B16.9)
  • 1” (DN 25) - PN 16
  • 1” (DN 25) - PN 40

Flange Size - 2-1/2” (DN 65)

  • 2-1/2” (DN 65) - 150# (ANSI B16.9)
  • 2-1/2” (DN 65) - 300# (ANSI B16.9)

Flange Size - 2” (DN 50)

  • 2” (DN 50) - 150# (ANSI B16.9)
  • 2” (DN 50) - 300# (ANSI B16.9)
  • 2” (DN 50) - PN 16
  • 2” (DN 50) - PN 40

Flange Size - 3” (DN 80)

  • 3” (DN 80) - 150# (ANSI B16.9)
  • 3” (DN 80) - 300# (ANSI B16.9)
  • 3” (DN 80) - PN 16
  • 3” (DN 80) - PN 40

Flange Size - 4” (DN 100)

  • 4” (DN 100) - 150# (ANSI B16.9)
  • 4” (DN 100) - 300# (ANSI B16.9)
  • 4” (DN 100) - PN 16
  • 4” (DN 100) - PN 40

Flange Size - 6” (DN 150)

  • 6” (DN 150) - 150# (ANSI B16.9)
  • 6” (DN 150) - 300# (ANSI B16.9)
  • 6” (DN 150) - PN 16
  • 6” (DN 150) - PN 40

Flange Type

  • Raised Face (RF)

Humidity

  • 10 to 55 % Relative Humidity

Loop Resistance

  • 700 ohms at 24 Vdc, Max.

NPT Connection

  • 1” NPT Male
  • 1/2” NPT Male
  • 3/4” NPT Male

Output

  • 4-20 mA, Loop Powered

Power Supply Effect

  • < 0.1 % of Output at, Max.

Pressure Range

  • bar: 1 to 34
  • kPa: 100 to 3,400
  • psi: 14.5 to 500

Process Connection Material

  • 316L Stainless Steel
  • Carbon Steel
  • Hastelloy C-276
  • PFA (Non-hazardous)
  • PTFE (Non-hazardous)

Response Time

  • 2 to 30 seconds with Adjustable Damping Time
  • Less than 2 to 3 seconds with No Damping Time

Sensor, Probe Diameter

  • Probe O.D.: 0.75” (19 mm) for Concentric Shield
  • Probe O.D.: 1/2” (12.7 mm) for General-purpose

Sensor, Probe Material

  • Probe: 316L Stainless Steel Rod
  • Probe: Hastelloy C-276 Rod
  • Probe: PFA Fully Insulated Rod
  • Probe: PTFE Fully Insulated Rod

Supply Voltage

  • 12-30 Vdc

show more